What are the Do's and Don'ts regarding subsea fittings?
asked
Sep 28, 2015
in
Subsea
by
pasmith
(
3,320
points)
fitting
subsea
Please
log in
or
register
to add a comment.
Please
log in
or
register
to answer this question.
1 Answer
+1
vote
answered
Sep 29, 2015
by
DavidNivola
(
475
points)
Do's:
Where fittings are necessary (e.g., connection to actuator) the fitting type should be SAE thread with 37-degree bottom taper conforming to SAE standard J514, Ferulok, or special Autoclave AF anti-vibration fitting.
Additionally, the J475, SAE straight thread with O-ring should be acceptable on the actuator spring chamber to seachest port.
Ferulok tube and reducers should be welded to the back of hydraulic couplers, etc., rather than pipe threaded connections.
You should ensure that any type of threaded fitting will withstand external ambient pressure at depth.
Fitting assembly torque should be independently verified and sealed/secured to ensure that the fitting has been properly made up and inspected.
Some means should be added to all threaded fittings to prevent loosening. This can be by wire locking, addition of a clamp over the fitting, or some other method accepted by industry. If wire locking is chosen, it is preferred to be done with 0.035 in. diameter Inconel 625 wire. This requires that a 0.040 in. (minimum) hole be drilled through at least one corner of the hexagon-shaped portion of each fitting (if applicable).
In addition, due to field history, Autoclave AE anti-vibration fittings should also be additionally locked by one of the methods noted above.
Further, not wire locking threaded plug fittings into valves is acceptable because the other end is welded to control tubing (with our current specs), which would prevent the plug turning out of the valve.
Don’ts:
National Pipe Thread (NPT) fittings should not be used for permanently installed subsea equipment. The use of Teflon tape, paste, or any other sealant material is prohibited.
No 17-4 ph ferules should be used in this application.
Please
log in
or
register
to add a comment.
Related questions
1
answer
Compression Fittings – Do’s and Don’ts
asked
Jun 5, 2016
in
Engineering
by
Normandy
(
21,000
points)
compression
fitting
1
answer
What are the general welding requirements used in subsea environment?
asked
Apr 26, 2016
in
Offshore-Upstream
by
Jarredd Tomlinson
(
360
points)
welding
subsea
1
answer
Constructability Suggestions for Contracting Strategy for Subsea Equipment Vendor (SEV) and Subsea Installation Contractor (SIC)
asked
Aug 30, 2018
in
Subsea
by
Habib Ramini
(
710
points)
subsea
constructability
1
answer
Subsea equipment insulation?
asked
Mar 3, 2016
in
Subsea
by
rbidong
(
880
points)
insulation
subsea
2
answers
Subsea Structures Installation Tolerances
asked
Jan 31, 2015
in
Subsea
by
pasmith
(
3,320
points)
plet
tolerance
subsea
tree
riser
Ask a Question
All categories
Engineering
(544)
Offshore-Upstream
(188)
Drilling
(27)
Subsea
(30)
Hull
(10)
Marine
(14)
Operations
(32)
Accomodation
(1)
Construction
(2)
Installation
(5)
Commission
(2)
Downstream-Midstream
(3)
Quality Assurance
(9)
Commercial
(10)
Procurement
(2)
Others
(15)
Most popular tags
fpso
valve
riser
pump
subsea
compressor
psv
flare
heat-exchanger
pressure
drilling
relief
corrosion
sour
tank
...